Driver Support Document

Nortel Contivity VPN switches, 600, 1100, 1700, 2500, 2600, 4500, 4600 & 5000 series

Show Tested Devices Grid

SYSOID Mapping
SYSOID MODEL OS VERSION
 1.3.6.1.4.1.2505.1 contivity 4.x
 1.3.6.1.4.1.2505.2 contivityExtranetSwitch2000 4.x
 1.3.6.1.4.1.2505.3 contivityExtranetSwitch1000 4.x, 5.x, 6.x
 1.3.6.1.4.1.2505.4 contivityExtranetSwitch4500 4.x, 5.x, 6.x
 1.3.6.1.4.1.2505.5 contivityExtranetSwitch15XX 4.x, 5.x, 6.x
 1.3.6.1.4.1.2505.6 contivityExtranetSwitch2500 4.x
 1.3.6.1.4.1.2505.7 contivityExtranetSwitch1600 4.x, 5.x, 6.x
 1.3.6.1.4.1.2505.8 contivityExtranetSwitch2600 4.x
 1.3.6.1.4.1.2505.9 contivityExtranetSwitch4600 4.x, 5.x, 6.x
 1.3.6.1.4.1.2505.600 contivityExtranetSwitch600 4.x, 5.x, 6.x
 1.3.6.1.4.1.2505.1100 contivityExtranetSwitch1100 4.x, 5.x, 6.x
 1.3.6.1.4.1.2505.1700 contivityExtranetSwitch1700 4.x, 5.x, 6.x
 1.3.6.1.4.1.2505.1740 contivityExtranetSwitch1740 4.x, 5.x, 6.x
 1.3.6.1.4.1.2505.1750 contivityExtranetSwitch1750 4.x, 5.x, 6.x
 1.3.6.1.4.1.2505.2700 contivityExtranetSwitch2700 4.x
 1.3.6.1.4.1.2505.5000 contivityExtranetSwitch5000 4.x

Driver Features Support Grid

Driver FeaturesAccess Methods
(X signifies feature support)CLISNMPTFTPCLI+TFTPSNMP+TFTPFTPCLI+FTPSNMP+FTPCLI+SFTPSCPCLI+SCPSNMP+SCPHTTP/HTTPS
X Driver Discovery   X X                      
X General Access  
(CLI protocols: telnet, ssh1, ssh2, console)
X         X              
Configuration
X Retrieve Running Configuration   X         X              
  Retrieve Startup Configuration                            
  Retrieve Binary Configuration                            
X Device information parsing  
X Enhanced Layer2 Basic IP information parsing  
X Configuration Deployment to Running   X         X              
  Configuration Deployment to Startup                            
  Binary Configuration Deployment                            
Diagnostics
X Routing Table   X                        
X OSPF Neighbors   X                        
X Interfaces   X                        
X Modules and Inventory     X                      
  Flash Storage Space                            
  File System                            
X Uptime     X                      
X ICMP Test   X                        
X Topology Parsing   X                        
  Duplex Parsing                            
  Enhanced VLAN Parsing  
Features
X Software Center release notes             X            
  Software Image Synchronization release notes                          
X Password Management  
(Can modify: full username, full password)
X                        
X Syslog Configuration and Change Detection   Syslog patterns X                        
X Custom Scripts and Diagnostics  
Bulk deploy available
X                        
X ACL Parsing  
X ACL Provisioning   X                        
  VLAN Provisioning                            
X Configlet Parsing  
  QoS Parsing  
  VRF Parsing  
  Context Management                            

Software Center

Release Notes

Update Device Software task

Updating software on Contivity devices uses a CLI command that requires the specification of the software version for the provided file. The filename used in the corresponding image set must contain this version number in the following form: V06_05.171.tar.gz. After the file is copied to the device by Update Device Software task, the device must be rebooted to fully install the update.

return to top

Syslog Triggering

return to top