Troubleshoot > Troubleshooting and Limitations – HPE Product Integrations > Troubleshooting and Limitations – SE Integration

Troubleshooting and Limitations – SE Integration

This section describes troubleshooting and limitations of Storage Essentials Integration.

  • Problem: If the SE system has duplicate entries for nodes, switches or arrays, the job produces the following error message: "Process validator error: multiple updates in bulk...".

  • Solution: This is expected behavior and does not affect population of valid CIs into UCMDB. To prevent this error message, duplicates must be removed from the SE system.

  • Error message: "Please use the SE database with SID 'REPORT' for this integration."

    Solution: For integration with SE 9.4 or higher, you should configure the integration point for a REPORT database instance (and not for an APPIQ instance as applied for SE versions up to and including 6.3).

  • Limitation: The credentials used for integration with SE should have access to the relevant materialized view status table as detailed below:

    Storage Essentials Materialized View Status Table

    Version 6.03 and earlier

    appiq_system.mview_status

    Later than Version 6.03 and earlier than Version 6.1

    appiq_system.mviewcore_status

    and

    appiq_system.mview_status

    Later than Version 6.1 and earlier than Version 9.4

    appiq_system.mview_module_status

    Version 9.4 and later

    appiq_system.mv_report_user_status

  • Limitation: If the discovery does not find a valid IP address and serial number for a VMWare ESX server in the HPE Storage Essentials database, that VMware ESX server is not reported to UCMDB.