Agent Configuration for Complete Installation Page

Enables you to make configurations for the Universal Discovery Agent installation when you select the Complete Installation mode.

Important information
  • The Windows computer must be running Microsoft Installer version 2.0 or later.
  • This page is displayed only if you selected Complete Installation on the Set Up Page.
Wizard map

The Agent Configuration Wizard contains:

Set Up Type Page > Agent Configuration for Complete Installation Page > Software Utilization Page> Uninstall Options Page > Uninstall Type Page

 

UI Element Description
Port

Select the port that you want to use for communication between the Universal Discovery Agent and the Data Flow Probe.

Note  This port number should be the same as the port number you specified in the UD Protocol Parameters dialog box at Data Flow Management > Data Flow Probe Setup > Domains and Probes > Domain > Credentials. Additionally, if you change this port number manually after installation, the new port number takes effect only after the Universal Discovery Agent is upgraded.

Time Out

Enter a value that sets a time out threshold.

Measured in seconds.

Note  This parameter is called Call Home Frequency in the Infrastructure Discovery activity.

Primary Call Home Probe Address

Enter a primary address for the Data Flow Probe server that you want the Universal Discovery Agent to contact for Call Home messages.

Use one of the following formats:

  • Hostname (For example: probehost)

  • IP Address (the call home port is 80)

    • IPv4Address (For example: 10.11.12.13)
    • IPv6Address (For example: 2010:836b:4179::836b:4179)

  • Full Path (the call home port is not 80)

    • http://HostNameOrIPv4Address:Port/callhome (For example: http://probehost:<port_number>/callhome)
    • http://[IPv6Address]:Port/callhome (For example: http://[ 2010:836b:4179::836b:4179]:<port_number>/callhome)

Note  

Port 80 is used by default when no port number is specified. If port 80 is occupied, use a format that specifies a customer port.

Secondary Call Home Probe Address Enter a secondary address for the Data Flow Probe server that you want the Universal Discovery Agent to contact for Call Home messages. See Primary Call Home Probe Address (above) for formatting information.
Certificate Path

Select a credential to use.

For more information on exporting certificate files, see Universal Discovery Agent Certificates.

Note  The path must be a folder that contains the asctrust.cert file and agentca.pem file.