Integrate > Third Party Integrations > HPE OneView Pull Integration > Create an Integration Point between HPE OneView and UCMDB

Create an Integration Point between HPE OneView and UCMDB

  1. Log on to UCMDB as an administrator.
  2. Navigate to Data Flow Management > Integration Studio. A list of existing integration points is displayed.

  3. Click New Integration Point . The New Integration Point dialog box opens.

  4. Complete the Integration Properties and Adapter Properties fields as shown in the following table:

    Field
    (*Required)

    Description
    Integration Properties section
    *Integration Name Type the name (unique key) of the integration point.
    Integration Description Type a description of the current integration point.

    *Adapter

    Click and then select HP Software Products / Micro Focus Products > OneView Integration.

    *Is Integration Activated? Select this option to indicate the integration point is active.
    Adapter Properties section
    *Credentials ID

    Click the Select Credential Id button. The Generic Protocol is already selected in the Protocol pane and in the Credentials list.

    Note  

    • Other credentials are not supported.
    • Ensure that the account has Read access to OneView.

    To configure the credential for this integration point,

    1. Ensure the Generic Protocol is selected, and then click . The Generic Protocols Parameters dialog box opens.
    2. Provide values for the following fields and click OK:

      • Network Scope: Use the default value ALL.
      • User Label: Type a label for the credential.
      • User Name: Provide the user name for the OneView account.
      • Password: Click and provide the password for the OneView account.
    3. Click OK twice.
    *OneView URL The URL of OneView.
    Trust All SSL Certificates

    Specifies whether to trust all SSL certificates when the OneView server does not have a valid certificate.

    Type one of the following values:

    True. Trust all SSL certificates.

    False. Do not trust all SSL certificates.

    Default value: True

    *Data Flow Probe

    The name of the Data Flow Probe/Integration service used to execute the synchronization from.

    Select IntegrationService for this integration.

    Note If the IntegrationService option does not exist, consult with your UCMDB administrator for the best selection for your requirements.

    Trigger CI Instance

    Click and select one of the following options from the drop-down menu:

    Select Existing CI. Select this option only if you want to select a valid, existing CI. The Select Existing CI pane appears.

    Create New CI. Select this option if you want to create a new CI. The Topology CI Creation Wizard appears. Complete the creation of the CI using the Wizard.

    Note For details on the Topology CI Creation Wizard, see "Topology CI Creation Wizard" in the Data Flow Management section of the UCMDB Help.

  5. Click OK.

    The integration point is created and its details are displayed.

    Note  

    • Your settings are not saved to the server until you click OK.
    • You can edit this integration point by selecting the Integration Point name in the Integration Point pane and then clicking .

  6. (Optional) To start the job immediately, click to perform a full synchronization.

    Note  

    • The first Full Synchronization may take a while to complete.
    • If you do not want the job to begin immediately, the job will be scheduled to run.

To see results of the job, perform the following:

  1. In Integration Studio, in the Integration Job pane, right-click the OneView job.
  2. In the drop-down menu, click Show Results of Job.

    Note  

    • The results of the previous job run that are stored in the Probe's database are displayed.
    • If the job has not yet run, the following message is displayed: "no results found on selected job".
    • Results are only displayed when jobs are run successfully.