Import XLF Crystal Reports into Linux BOE 4.1 SP2

To import XLF Crystal reports into Linux BOE 4.1 SP2, proceed as follows:

  1. Open BOE Dashboard.
  2. Create an XLF Crystal report or open an existing XSL Crystal report.
  3. Click File > Save To Platform As > Dashboards Object to Replace Flash Object, input Linux BOE server IP, port, user name, password and Enterprise, and then click OK. If the procedure proceeds without error, go to step 13.
  4. If the Transport error: Communication failure.(FWM 00001) error message is displayed:

    1. Re-input the Windows BOE server IP, port, user name, password and Enterprise, and then click OK to import the XLS Crystal report into windows BOE.
    2. Go to the Linux BOE server, and edit /etc/hosts with the root user to input the Windows BOE server's full name and IP address.
    3. Go to the Windows BOE server, and open Linux BOE CMC.
    4. Click Promotion Management.
    5. Click the New Job menu. In the Source dropdown list, click Login to a New CMS, and then input the relevant Windows BOE log on information.
    6. In the destination dropdown list, select Login to a New CMS, and input the relevant Linux BOE log on information.
    7. Click Create to create the relevant job.
    8. In the pop up window, click Add Objects from the system page, select the XLF Crystal report to be imported, and then click Add & Close.
    9. Select the XLF Crystal report to be imported, and click Promote in the toolbar.
  5. After the job is done, the XLFCrystal report is imported into Linux BOE.