Integrate > Microsoft SCOM > Configure > Adjusting OMi Settings

Adjusting OMi Settings

To increase robustness of your Microsoft SCOM topology integration with OMi, you must adjust the setting for a particular configuration type attribute in OMi. Additionally, to avoid problems caused by a complex monitored infrastructure, you may want to adjust an OMi setting for data chunking.

Note: Service provider recommends that you perform the procedure for adjustment of the External ID attribute in any case.

Configuration Type Attribute: External ID

Fully qualified domain names (FQDNs) of the monitored systems might be relatively long. To accommodate longer FQDNs, adjust the size of the External ID attribute of the Data configuration item (CI) type in OMi. Follow the steps:

  1. Log on to the OMi web interface.

  2. Navigate to Administration > Setup and Maintenance > Infrastructure Settings.

  3. Click the Foundations button.

  4. From the Foundations drop-down list, select RTSM.

  5. In the RTSM - General Settings part, click the (Edit) icon on the right-hand side of the Object Root line.

  6. In the Edit Setting window, replace the content of the Value text box with the root string.

  7. To apply changes and close the window, click Save.

  8. Navigate to Administration > RTSM Administration > Modeling > CI Type Manager.

  9. In the CI Types pane, in the Root part, select Data.

  10. In the toolbar, click Attributes.

  11. In the Display Name column, select External ID.

  12. Click the (Edit) icon in the toolbar.

  13. In the Details page of the Edit Attribute window, replace the default value in the Value Size text box (50) with a suitably higher value. For example, you can specify the value 100.

  14. To apply changes and close the window, click OK.

RTSM Setting: Data Push Chunk Size

If the infrastructure monitored by Microsoft SCOM is relatively large, the quantity of the forwarded topology data is also large, at least the content sent in response to the initial collection query. In such circumstances, to avoid disruptions in topology forwarding, increase the data push chunk size in OMi. Follow the steps:

  1. Log on to the OMi web interface.

  2. Navigate to Administration > Setup and Maintenance > Infrastructure Settings.

  3. Click the Foundations button.

  4. From the Foundations drop-down list, select RTSM Fuses.

  5. In the RTSM Fuses - Fuses Settings part, click the (Edit) icon on the right-hand side of the Data Push Chunk Size.

  6. In the Edit Setting window, in the Value text box, replace the default value (2000) with a suitably higher value. For example, you can specify the value 20000.

When the entire Microsoft SCOM topology is available in OMi, you can revert the Data Push Chunk Size option to its predefined value to avoid potential decrease in OMi performance.