Use > Data Flow Management > Universal Discovery > Inventory Discovery > How to Run Inventory Discovery Manually

How to Run Inventory Discovery Manually

This task describes how to run inventory discovery manually.

  1. Prerequisites

    • Ensure that a Data Flow Probe server is running.
    • Ensure that UCMDB is running.
  2. Configure the scanners

    Generate a scanner using the Scanner Generator Wizard. For more information, see Scanner Generator Wizard.

    Note Ensure you select Manual Mode in the Scanner Generator Wizard.

  3. Distribute the scanners

    Connect to discovery nodes using any remote access technology to copy the scanner executable file to the discovery node.

  4. Run the scanners

    Methods to run scanners are as follows:

    • Attended

      Click the executable file. To see a list of default file names, see Scanners tab.

    • Unattended

      Connect to the discovery nodes using any remote access technology, third party solution, or scripting solution and then run the scanner executable file. To see a list of default file names, see Scanners tab. You can pass command line parameters to the discovery node shell to override any configurations that were used in the Scanner Generator. For more information about scanner command line options, see Scanner Command Line Parameters Overview.

  5. Save the scan files to the Data Flow Probe

    Methods to save the scan file to the Data Flow Probe are as follows:

  6. Run inventory discovery job

    Run the Inventory Discovery by Manual Scanner Deployment job. For more information, see How to Manually Activate Modules/Jobs/CIs.

  7. Results

    To verify the discovery ran successfully, select the Management Zone in the Management Zones tree. In the Discovery Status pane, click the Results tab.

    Note If you are not using Management Zones, click the Inventory Discovery job.

    For user interface details, see Discovery Results Tab/Pane.

Related Topics Link IconRelated Information