Use > Data Flow Management > Data Flow Management Setup > Data Flow Probe Setup > How to Clear Data Flow Probe Data

How to Clear Data Flow Probe Data

This task describes how to clear the data from the Data Flow Probe.

Note For details on clearing the data from the UCMDB Integration Service, see How to Clear UCMDB Integration Service Data.

  1. Stop the Data Flow Probe service. To do this, see How to Stop a Data Flow Probe.

  2. Run the clearProbeData script

    Note The clearProbeData script resets the Data Flow Probe's DB schemas and file system state. After running this script the Data Flow Probe resends all the discovered data to UCMDB. This could potentially create a significant load on the UCMDB Server.

    Windows
    1. On the Data Flow Probe machine, go to:

      c:\UCMDB\DataFlowProbe\tools

    2. At the command prompt, type:

      clearProbeData.bat

    Linux /opt/UCMDB/DataFlowProbe/tools/clearProbeData.sh
  3. Restart the Data Flow Probe service

    Start the Data Flow Probe service. For details, see How to Start a Data Flow Probe.

  4. Results

    All the data is deleted from the Data Flow Probe.