Configure an event forwarding rule in Operations Manager i (OMi)

Once you have configured the HPE Service Manager server as a connected server in HPE Business Service Management (BSM) Operations Management i (OMi), you need to configure an event forwarding rule for the OMi server to forward events to Service Manager.

  1. Log on to BSM as a system administrator.

  2. Navigate to Admin > Operations Management > Event Automation.
  3. Click the New Item button.
  4. In the Display Name field, enter a name for the rule. For example, smserver1.
  5. In the Event Filter field, select Critical.
  6. In the Target Servers field, select the Service Manager server you configured as a connected server, and then click the Add button.

    The details of the target server are displayed.

  7. In the Forwarding Type field, select Synchronize and Transfer Control.
  8. Click OK.

    The forwarding rule is displayed in the Event Forwarding Rules section.