Searching the Help
To search for information in the Help, type a word or phrase in the Search box. When you enter a group of words, OR is inferred. You can use Boolean operators to refine your search.
Results returned are case insensitive. However, results ranking takes case into account and assigns higher scores to case matches. Therefore, a search for "cats" followed by a search for "Cats" would return the same number of Help topics, but the order in which the topics are listed would be different.
Search for | Example | Results |
---|---|---|
A single word | cat
|
Topics that contain the word "cat". You will also find its grammatical variations, such as "cats". |
A phrase. You can specify that the search results contain a specific phrase. |
"cat food" (quotation marks) |
Topics that contain the literal phrase "cat food" and all its grammatical variations. Without the quotation marks, the query is equivalent to specifying an OR operator, which finds topics with one of the individual words instead of the phrase. |
Search for | Operator | Example |
---|---|---|
Two or more words in the same topic |
|
|
Either word in a topic |
|
|
Topics that do not contain a specific word or phrase |
|
|
Topics that contain one string and do not contain another | ^ (caret) |
cat ^ mouse
|
A combination of search types | ( ) parentheses |
|
- Connection parameters
- Special parameters: allowwsdlretrieval
- Startup parameter: compress_soap
- Parameter: disableWSEss
- Startup parameter: emailout
- Parameter: enablecoredump
- Parameter: group
- Parameter: groupmcastaddress
- Parameter: groupname
- Parameter: groupport
- Parameter: host
- Parameter: httpPort
- Parameter: httpsPort
- Parameter: licensefile
- Parameter: loadBalancer
- Startup parameter: ntservice
- Parameter: pid
- Parameter: preferredFQHN
- Startup parameter: quiesce
- Parameter: reportlbstatus
- Parameter: requestviaproxy
- Parameter: restart
- Parameter: restartGraceInterval
- Parameter: restartRandMax
- Parameter: scauto
- Parameter: scautolistener
- Startup parameter: shutdown
- Parameter: sslConnector
- Startup parameter: system
- Parameter: threadTerminateWait
- Parameter: updatelicense
- Parameter: useHostinWSDL
- Parameter: useIPinWSDL
- Parameter: ws_endpoint
- Startup parameter: webservices_sessiontimeout
- Startup parameter: connectionTimeout
- Parameter: smartemailTimeout
Startup parameter: connectionTimeout
Startup parameters change the behavior of the Service Manager server. You can always set a startup parameter from the server's operating system command prompt.
Parameter
connectionTimeout
Description
This parameter defines the number of milliseconds that the server waits for a Service Manager client request before the server assumes that the client connection has timed out and closes the connection.
- The timeout limit for the connectionTimeout parameter should be longer than that for the webservices_sessiontimeout parameter. Otherwise, the client session could not be reused. It is recommended that you set the value of the connectionTimeout parameter no less than 60000 milliseconds.
- A value that is 30 seconds shorter than the value of the connectionTimeout parameter is automatically applied for the timeout limit of a web service if the Service Manager connection is kept alive.
Valid if set from
Server's operating system command prompt
Initialization file (sm.ini)
Requires restart of the Service Manager server?
Yes
Default value
60000
Possible values
At least 45000
Example usage
Command line: sm -httpPort:13080 -connectionTimeout:80000
Initialization file: connectionTimeout:80000
Related topics
Related topics
Enter a parameter in the sm.ini file
Related topics