Configure Polling

QoS Polling

You can set the polling interval for the QoS/Juniper CoS interfaces or actions that are not part of any QA group by specifying the value in the Polling Interval field in the QoS Polling tab.

If the QoS interfaces or actions are part of a QA group and no polling frequency is specified for that group, it will take the default value, which is 5 minutes.

To configure the QoS polling interval:

  1. In the NNMi console, go to the Configuration workspace and click Quality Assurance Configuration Console. The NNM iSPI Performance for QA Configuration console opens.

  2. In the Configuration workspace, select Polling Configuration. The Polling Configuration form opens.

  3. Select the QoS Polling tab.

  4. Specify the polling interval in seconds in the Polling Interval field.

    You cannot use a polling interval that is less than 1 minute.

  5. You can perform the following tasks using the Polling Configuration form:

    Icon Description
    Close Closes without saving the polling interval details you specified.
    Save Saves the polling interval details you specified.
    Save and Close Saves the polling interval details you specified and closes the Polling Configuration form.

It is recommended that you configure at least 300 seconds or a higher value for all QoS interfaces. To poll select interfaces with a higher frequency, use the QA Group-based polling.

Probe Polling

NNM iSPI Performance for QA enables you to override the probe-specific polling frequency by applying the global polling frequency for the QA probes.

QA probe retains the probe-specific polling frequency only if its frequency is higher than the global polling frequency.

To override the probe-specific polling interval:

  1. In the NNMi console, go to the Configuration workspace and click Quality Assurance Configuration Console. The NNM iSPI Performance for QA Configuration console opens.

  2. In the Configuration workspace, select Polling Configuration. The Polling Configuration form opens.

  3. Select the Probes Polling tab.
  4. Specify the polling interval in seconds in the Polling Frequency field.

    You cannot use a polling interval that is less than 1 minute.

  5. Select the Override Probe Specific Polling Interval check box to apply the global polling frequency for the QA probes.
  6. You can perform the following tasks using the Polling Configuration form:

Icon Description
Close Closes without saving the polling interval details you specified.
Save Saves the polling interval details you specified.
Save and Close Saves the polling interval details you specified and closes the Polling Configuration form.