Administer > NNMi State Polling > Configure State Polling > Configure Node Monitoring

Configure Node Monitoring

If an object does not qualify for any configured interface group, State Poller evaluates the object for membership in node groups. Settings are applied to the first node group match from the lowest ordering number to the highest ordering number.

For each node group, open the Monitoring Configuration form, and then, open the Node Settings tab. Create a custom set of instructions as to how State Poller should handle that group. Your instructions can include:

  • Enabling or disabling fault monitoring
  • Setting the fault polling interval
  • Enabling or disabling performance polling if you have the NNM iSPI Performance for Metrics
  • Setting the performance polling interval if you have the NNM iSPI Performance for Metrics
  • Setting performance management thresholds if you have the NNM iSPI Performance for Metrics
  • Selecting whether NNMi should monitor unconnected interfaces (or unconnected interfaces hosting IP addresses) in the group

You might configure different settings for each node group.

Tip Double-check the order numbers, keeping in mind that an object that qualifies for multiple groups has settings applied from the group with the lowest order number.